Angle of the rotary sensor head 180 degree (hold each 45 degree)                         Application Example 
Check the charge condition of film, resin, etc.

ESD check at the assembling process line

Check the ion balance of the ionizer

 

Specification

Model DZ4
Signal detection method Oscillating chopper *1
Frequency of data indication Each 0.5 second
Measurement range Normal mode: 0.01~19.99 kV
I.B mode: 0.001~1.999 kV
Measurement accuracy ±10%rdg ± 2 digit
Measurement distance 30 mm (between measurement object and sensor)
Measurement distance adjust Red Light focusing system
Angle of the rotary sensor head 180 degree (hold each 45 degree)
Indicator LED indicator with back light
Polarity display Both positive and negative polarity
Mode select With MODE select button
Battery check Indicate in LED indicator
Power supply DC 9V alkaline battery 006P
Operating Environment 0 to 40℃
From 70% or less with no condensation
Main unit dimensions 66×22×138 mm (W×H×D)
Wight 160 g
Accessories 9V battery, soft storage case, Grounding Cable Strap
*1: The oscillating chopper is very susceptible to shock such as being dropped. Take care not to subject when using it.

Dimensional Diagram